Correcting phase polarity wiring, Wiring overview – Woodstock SB1039F User Manual

Page 94

Advertising
background image

-88-

For Machines Mfg. Since 5/11

14" TURN-X

®

Toolroom Lathe

E L E C T R I C A L

Correcting Phase Polarity Wiring

This sub-section is only provided for

troubleshooting. If you discover during the test

run that the lathe will not operate, or that the

spindle runs backwards, the lathe may be wired

out of phase. Without the proper test equipment

to determine the phase of power source legs,

wiring machinery to 3-phase power may require

trial-and-error. Correcting this is simply a

matter of reversing the positions where two of

the incoming power source wires are connected.

To correct wiring that is out of phase:

1. Push the STOP button, turn the master

power switch to OFF, and disconnect the

machine from power.

2. Open the electrical box and swap any two hot

wires coming from the plug, as illustrated in

Figure 138.

To Plug

Hot

L3

L2

L1

Gn

Ground

1

2

5

3

6

4

MASTER

POWER SWITCH

Hot

Hot

Swap any two

of these wires

Figure 138. Swapping L1 and L2 power connections

to correct out-of-phase wiring.

3. Close and latch the electrical box, and

reconnect the machine to the power source.

Wiring Overview

Power Supply

Connection

Page 95

Work Lamp

Page 95

Spindle

Switches

Page 94

Coolant

Pump Motor

Page 92

Control Panel

Page 94

Spindle Motor

Page 92

End Gear Cover

Safety Switch

Page 95

Brake Pedal

Safety Switch

Page 95

Chuck Guard

Safety Switch

Page 95

Electrical

Cabinet

Page 90

Advertising