4. Door Lock Pulse Length. Selects between a 1-second and a 3-second output for door locking and

unlocking. Program to 3 seconds for vehicles equipped with vacuum door locking systems.

5. Aux 2 Auto Activate with Arm. When selected, the Auxiliary 2 output will activate when the system

is armed. This feature can be used to roll-up windows, close sunroofs, activate accessories, etc.

6. Auxiliary 1 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 1.

Momentary operation provides an output for as long as the transmitter button is pressed.
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and remains
on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be
programmed to output for 1 second up to 255 seconds.

7.

Auxiliary 2 Mode. Selects from Momentary, Timed, or Latched operation for Auxiliary 2.

8. Disarm with Auxiliary 1. When selected, activating the Auxiliary 1 output (usually used to open the

trunk) will disarm the alarm.

9. Start in Valet Mode. Selects whether or not the vehicle can remote start while in the valet mode.
10. Lock After Start. When selected, the doors will automatically lock after remote starting.
11. Lock After Shutdown. When selected, the doors will automatically lock after remote shutdown.
12. Engine Run Time. Selects between 15 or 25 minutes for the remote start run cycle.
13. Automatic Start Mode. Selects between every two hours or every hour for the automatic engine

starting feature.

Branch

Feature

Button 1 (default)

Button 2

Button 3

1. Ignition Door Locking

On

Off

2. Ignition Door Unlocking

Unlock All

Unlock Driver Only

Off

3. Door Unlock Pulse

Single

Double

4. Door Lock Pulse Length

1 second

3 seconds

5. Aux 2 Activate on Lock

Off

On

6. Aux 1 Mode

Pulsed

Timed

Latched

7. Aux 2 Mode

Pulsed

Timed

Latched

8. not used
9. Start in Valet Mode

Disable

Enabled

10. Lock after Start

On

Off

11. Lock after Shutdown

On

Off

12. Engine Run Time

15 minutes

25 minutes

13. Automatic Start Mode

2 hours

1 hour

14. Engine Sense Mode

Tachless

Tach Monitor

15. Remote Start Program

RPM Learn

Gas Engine

Diesel Engine

16. FM Transmitter Program

not used

FM Remote Learn

17. Ignition 2 Output Program

Ignition 2 Output

Accessory 2 Output

Starter 2 Output

18. Horn Honk Output

Horn Output

Ignition 3 Output

19. Turbo Mode

Disabled

Enabled