33 fu91, With mode switching, 34 fu91 m – Simrad ROBERTSON AP45 User Manual

Page 79: Ultiple installation

Advertising
background image

Robertson AP45 Autopilot
Installation

Simrad Robertson AS

Egersund - Norway

Page 5-29

Fig. 5-33

FU91 with mode switching

The two diodes (1N4002 or similar) and the resistor can be mounted either in the
AP45 J3 connector or in the FU91 terminal board. By giving resistor R different
values, following mode changes are possible:

R = 1.0K: Auto

Dodge

Auto

R = 3.0K: Auto

Manual

Manual

R = 5.1K: Auto

Manual

Auto

See also page 2-14 for operation.

Multiple FU91 installation is not recommended with AP45 unless the optional FU-
Junction box is used. Connections are shown in Fig. 5-34

If mode switching is required, the resistor and the two diodes must be mounted
between the FU-Junction box and the AP45 Control unit.

Fig. 5-34

FU91 Multiple installation