18

Electrical Requirements

For models 427 and 427R, the electrical supply should be

located within the shaded area shown in the illustration.

Follow the National Electrical Code and local codes and

ordinances when installing the receptacle. A separate

circuit, servicing only this appliance is required. A ground

fault circuit interrupter (GFCI) is not recommended and

may cause interruption of operation.

IMPORTANT NOTE:

For models 427 and 427R, the elec-

trical outlet must be placed so the grounding prong is to

the right of the thinner blades. The outlet must be flush

with the back wall.

Electrical Requirements

Power Supply

115 V AC, 60 Hz

Circuit Breaker

15 amp

Receptacle

3-prong grounding-type

13"

(330)

1

/

4

"

(6)

4

1

/

2

"

(114)

LEFT SIDE

OF OPENING

FLOOR

2

1

/

2

"

(64)

FRONT VIEW

Location of electrical supply.

Do not use an extension cord or two-prong adapter.

Electrical ground is required on this appliance. Do not

remove the power cord ground prong.

The outlet must be checked by a qualified electrician to

be sure that it is wired with the correct polarity and is

properly grounded.