Instructions for the installer, Final operations, 2 burner and nozzle characteristics table – Smeg A2-5 User Manual
Page 8: 3 arrangement of burners on cooking hob
 
Instructions for the installer
3.2
Burner and nozzle characteristics table
 
Burner 
Rated
heating
capacity
(kW)
LPG
–
G30/G31
28/37
mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1.05
50
30
360
76
75
Semi rapid
1.8
65
33
450
131
129
Rapid
3
85
45
750
218
215
Triple crown
3.3
91
68
1600
240
236
 
 
 
Burner 
Rated heating
capacity
(kW)
Natural gas – G20 20 mbar
Nozzle
diameter
1/100 mm
Reduced
flowrate
(W)
Auxiliary
1.05
72
360
Semi rapid
1.8
97
450
Rapid
3
115
750
Triple crown
3.5
133
1600
3.3
Arrangement of burners on cooking hob
BURNERS 
 
1
Auxiliary
2
Semi rapid
3
Rapid
4
Ultra rapid
5
Ultra rapid
4.
FINAL OPERATIONS
After replacing the nozzles, reposition the flame-spreader crowns, the 
burner caps and the grids. 
After adjustment to a different kind of gas from the one for which the 
cooker has been tested, replace the plate inside the storage 
compartment with one corresponding to the new kind of gas. This plate 
can be obtained from your nearest Authorised Assistance Centre. 
43