INSTALLATION INSTRUCTIONS

SK0-0055-001 HUMIDISTAT

The humidistat is designed for either return air duct or wall
mounting
. Packaged in a duct mount configuration, (For this type
mounting begin installation at the section labeled return air duct
installation on page 2.)
for conversion to a wall mount configuration
simply pull off the knob and remove the mounting screws and rotate the
control 180° and reattach the mounting base, (For this type mounting
begin installation at the section labeled wall mount installation on
page 3.)
.


DANGER

∗

Do not cut or drill any air-conditioning or electrical
accessories during installation.

∗

Fatal electrocution is possible if you contact a live wire.

∗

Electrical power can cause electrical shock

∗

Disconnect all electrical power supplied to the equipment
before beginning installation.

∗

Blindness can occur if freon contacts your eyes.

CAUTION

∗

Do not install on any electrical system over 30 VAC

CAUTION

∗

All electrical wiring should comply with codes and
ordinances.

At Outside Temperatures

Recommended Setting

-20°F -30°C

15%

-10°F -25°C

20%

0°F -20°C

25%

+10°F -10°C

30%

+20°F -5°C

35%

Over 20°F Over 0°C

40%

Recommended Settings

Warning:
Adjusting the
humidity control
higher than the rec-
ommended setting
may cause conden-
sation resulting in
possible damage to
the

home.