2
0

20

ELECTRICAL CONNECTION

• Connect the Hood to the Mains power sup-

ply, inserting a two-pole Switch with a con-
tact aperture of at least 3 mm.

• Remove the Metal grease filters (see par.

on “Maintenance”) and make sure that the
power supply Cable is properly inserted in
the Suction fan socket.

• Take the wires indicated in fig.1 and pass

them through the slot formed on the galva-
nized diffuser support, as shown in fig.2.

• Position the finishing plug 27 over the

housing in the diffuser support, fixing it us-
ing a screw 12e (2.9 x 9.5) and applying the
2 cable clamp elements 26 as indicated in
figs. 3 and 4.

• Connect the Controls Connector fig. 5.
• Connect the Lighting Connector fig. 6.
• Store both the Connectors in the Protective

box 24 and close it with 2 Screws 12e (2.9
x 9.5), provided.

• Remove the protective film from the dou-

ble-sided adhesive on the connection box,
and fix it inside the motor compartment fig.
7.