background image

5

Using the MZA 900 P as a cable tester

The MZA 900 P can also be used as a cable tester for XLR
microphone cables. For this, there is no need to connect a
microphone.

Connect one end of the cable to be tested to a mixing
console with activated phantom powering. Connect the
other end of the cable to the MZA 900 P.

LED lights up in green:
y The cable is OK

LED lights up in red. Possible errors:
y One signal wire is broken
y One signal wire is short-circuited to the shielding

LED does not light up. Possible errors:
y Both signal wires are broken
y The shielding is interrupted
y Both signal wires are short-circuited to the shielding