3

MAINTENANCE

SCHOTT PV modules are designed for long life and require very little maintenance. If the
angle of the PV module is 5 degrees or more, normal rainfall is usually sufficient to keep
the module glass surface clean under most weather conditions. If dirt build-up becomes
excessive, clean the glass surface only with a soft cloth using water. Do not use high
pressure spray or chemicals to clean the modules. If cleaning the back of the module is
required, take utmost care not to damage the back side materials. In order to ensure
proper operation of the system, please check all wiring connections and the condition of
the wire insulation periodically.

3.1

SPECIFICATIONS

POLY™ 230 POLY™ 225 POLY™ 220 POLY™ 217 POLY™ 210 POLY™ 202 POLY™ 195

Maximum Power

(P

max

)

230

225

220

217

210

202

195

Open Circuit voltage (V

oc

)

36.9

36.7

36.5

36.4

36.1

35.8

35.4

Short-Circuit Current (I

sc

)

8.33

8.24

8.15

8.10

7.95

7.79

7.61

Operating Voltage (V

mp

)

30.0

29.8

29.7

29.6

29.3

28.9

28.5

Current at Vp

max

(I

mp

)

7.66

7.55

7.41

7.33

7.16

6.99

6.84

Maximum System Voltage

600 V

600 V

600 V

600 V

600 V

600 V

600 V

Series Fuse Rating

(A)

15 A

15 A

15 A

15 A

15 A

15 A

15 A

Weight

50.6 lbs

50.6 lbs

50.6 lbs

50.6 lbs

50.6 lbs

50.6 lbs

50.6 lbs

Length

66.39”

66.39”

66.39”

66.39”

66.39”

66.39”

66.39”

Width

39.09”

39.09”

39.09”

39.09”

39.09”

39.09”

39.09”

Depth

1.97”

1.97”

1.97”

1.97”

1.97”

1.97”

1.97”

Maximum Load

Pressure: 3,600 N/m

2

or 75psf

Temperature Coefficients

Power

-0.47 % °C

Voc

-0.334 % °C

Isc

+0.03 % °C

The electrical characteristics are within ± 10 percent of the indicated values of Isc, Voc and Pmax under Standard Test
Conditions (irradiance of 100 mW/cm

2

, AM 1.5 spectrum, and a cell temperature of 77°F (25°C).

Advertising