3 grounds, 4 vcc - regulated power supply input, Grounds vcc - regulated power supply input – Sony Ericsson GR47/GR48 User Manual

Page 23

Advertising
background image

5. SYSTEM CONNECTOR INTERFACE

23

LZT 123 7589 R1A

• The SIM output signals and the SIMVCC supply will continuously

withstand a short circuit to any voltage within the range 0 V to 4.1V.

5.3 Grounds

There are two ground connections in the radio device, AGND (analogue
ground) and DGND (digital ground). Pin assignments are shown in the
table above.

1RWH

AGND and DGND are connected at a single point inside the radio device.
They must not be joined together in your application.

5.3.1 Analogue Ground - AGND

AGND is the return signal, or analogue audio reference, for ATMS (Audio
To Mobile Station) and AFMS (Audio From Mobile Station). It is
connected to the DGND inside the radio device only. The application must
not connect DGND and AGND.

5.3.2 Digital Ground - DGND

DGND is the reference or return signal for all system interface digital
signals and is also the d.c. return for SERVICE and the power supply, VCC.
Connect all DGND pins together in your application in order to carry the
current drawn by the radio device.

5.4 VCC - Regulated Power Supply Input

Power is supplied to the radio device VCC pins, from an external source.

Pin

Signal

Description

2, 4, 6, 8, 10, 12

DGND

Digital ground

60

AGND

Analogue ground

Parameter

Limit

I

max

12.5 mA

Parameter

Per Pin

Total (5 Pins)

I

max

< 6.0A

< 3.0A

I

avg

< 100mA

< 600mA

Pins

Signal

Description

1, 3, 5, 7, 9

VCC

regulated power supply input