• Do not modify the AC receptacle in any way.
• Use only 40-amp or 50-amp fuses. (Replaced by certified
technician only.)
• This device does not include an internal Ground Fault
Circuit Interrupter (GFCI). For GFCI protection, use a
Coleman Cable 02822 GFCI outlet.
WARNING: Handling the cord on this product or cords as-
sociated with accessories sold with this product, may expose
you to lead, a chemical known to the State of California to
cause cancer and birth defects or other reproductive harm.
Wash hands after handling.
BEfORE USING PID-760 POWER INvERTER
It is important to know the continuous wattage of the device
you plan to use with the inverter. The PID-760 must be used
with devices drawing 760 watts or less. If the wattage is not
marked on the device, an estimate can be made by multiply-
ing the AC input current (Amps) by the AC voltage (110V).
Devices like TVs, fans or electric motors require additional
power to start (commonly known as the “starting or peak
power”). The PID-760 can supply a momentary surge in
wattage; however even devices rated less than the maxi-
mum 760 watts can exceed the inverters surge capability
and cause an automatic overload shutdown.
Make sure the device you are using is compatible with a
modified sine wave inverter.