3 DISPLAY

Can indicate the program which will begin and the boiler/Tank
temperature.
In case of anomalies an error code will be indicated, for example
“E 1”
- Boiler temperature anomaly
- Tank temperature anomaly
- Tank loading anomaly
- Tank draining anomaly
- Boiler anomaly

Start button

Initiates the program shown on the display

L3

Bicolor led indictor

This led indicates the state of the machine

• Green indicates the machine is ready for a new program

• Red indicates the machine is busy with an operation

• Yellow indicates a break after Tank draining


MACHINE CONFIGURATION PARAMETERS (Intended for technical personnel, not the user)

Parameter Description

Range

Preset

P0

Drain cycle time

1-5’

1

P1 Boiler

temperature

60-95°C

82

P2 Tank

temperature

40-65°C

55

P3 Rinse

duration

10-40’’

13

P4

BOILER STOP option

YES/NO

1 YES

P5

Brief wash time

60-90

60

P6

Drain with overflow option

YES/NO

1 YES

P7

Cold rinse option

YES/NO

0 NO

P8

Regeneration option

YES/NO

1 YES

P9

Maximum water load duration

1-10’

10

P10

H2O Hardness (to be set by the user based on water hardness)

35

15

P11

Machine type

4

4

P12

Wash number counter

YES

1 YES

PARAMETER FUNCTION WITH MACHINE ON

Upon first installation it is possible to perform a series of operations which allow for the personalization of the
dishwasher based on the user’s necessities, as well as a test cycle which quickly checks the functionality of all of
the components. To perform these operations it is necessary to set the machine to “programming mode” as
described hereafter

Shut the machine off by pressing

‐ Simultaneously

press and

until P0 appears on the display

‐ With

the button (ahead) and the

button (back) select the programs

Once the parameter to modify has been identified, keep the

button pressed and modify the required

setting with the “ahead”

and “back”

buttons

Once the setting has been correctly modified, release the

button

When finished with the settings turn the machine off and on again by pressing

Note: always turn on the DRAIN PUMP function in machines with Air Tank or Break Tank even if absent.

IN PARAMETERIZATION MODE, IF NO BUTTON IS PRESSED WITHIN 30 SECONDS THE KEYBOARD SHUTS