Regular maintenance, Check / lubricate free-hand linkage, Lubricating the auger shaft & assembly – Snapper 1694602 9247E User Manual

Page 19

Advertising
background image

Regular Maintenance

18

CHECK / LUBRICATE FREE-HAND
LINKAGE

Check the function of the Free-Hand controls: the con-
trols should function as described in the CONTROLS
section. It is critical for the safe operation of the unit
that the controls disengage when released.

If the controls do not function properly, lubricate them. If
lubrication does not rectify the problem, see your dealer.
Under no circumstances should the unit be used if the
controls are not functioning properly.

Figure 16. Lubricate Free Hand Control

Figure 17. Lubricating the Auger Shaft Assembly
A. Grease Fittings

C. Cotter Pins

B. Shear Pins

D. Auger Assembly

A

B

D

C

LUBRICATING THE AUGER SHAFT &
ASSEMBLY

1. Remove cotter pin (C, Figure 17) and shear pin (B).

2. Use a grease gun and squirt several shots of grease

into grease fitting (A).

3. Rotate auger assembly (D) several times to distribute

the grease evenly. Repeat step 2.

4. Reinstall shear pin (B) and cotter pin (C).

5. Repeat procedure for other side.

A

B

D

C

Figure 15. Lubricate Free-Hand™ Control Linkage
A. DO NOT Lubricate Deflector Control

A

IMPORTANT NOTE

It is very important that grease fittings on the auger shaft
are lubricated regularly. If auger rusts to shaft, damage to
worm gear may occur if shear pins do not break.

Advertising