TCL Air Conditioner Service Manual

1 2

this, it displays the failure and the protection is failing. You must

power off/on to operate

it. In the failure, you can operate the FAN mode.

When the outdoor protects in the COOLING or DRY, the outdoor unit stops, the indoor fan operates in

set speed ; and in the HEATING, the outdoor unit stops, the indoor fan operates in cold air prevention
control. The system doesn’t receive the signal of remoter controller except the signal of shut off.
When the system check

s the voltage is 220V and the delay control is finished, it operates at normal

again.

When the indoor fan motor is failure, the compressor is stopped, the outdoor fan and indoor fan is

stopped and display the failure. The system doesn’t receive the signal of remoter controller except the
signal of shut

it off.

d) Display Of The Control

In the display board the lamp from left is the POWER lamp(Red), the SLEEP lamp(Yellow), the TIMER
lamp(Yellow), the RUN lamp(Green).

g) When

it gives the control power, the buzzer sounds long for 0.3 second per cycle.