Sonance One Zone Connecting Block CB1 User Manual

Page 2

Advertising
background image

SONANCE • 212 Avenida Fabricante • San Clemente, CA 92672

Tech Support (800) 582-0772 www.sonance.com

©2002 All rights reserved.

Pg 2

33-1892 8.02

7. Because of this current sharing feature, you may plug in any combination of emitter models E1, VE1, E2, &

VE2 to the CB1 (up to a maximum of 8
individual emitters) to drive the desired number of devices.
NOTE 1: Be sure the PS1 Power Supply is plugged into an un-switched AC outlet. This maintains
the system in "standby" operation so that power-on commands can be sent to the controlled
equipment.

IMPORTANT NOTE: When using long lengths (more than 200 feet) of inter-room shielded cable, it
may be necessary to connect a 470 ohm 1/8 watt resistor between input (signal) and GND at the
IR input terminals of Sonance Connecting Blocks, Zone Controllers, etc. Refer to Fig. 3. The
resistor discharges the cable capacitance more quietly, allowing IR codes of high bit rates to
pass without data loss.

MAIN ROOM, EQUIPMENT CABINET, ETC.

GND

OUT

+12V

ROOM 3

+12VDC

GND

GND

SIGNAL

OUT

GND

+12V

ROOM 1

ROOM 2

3-Wire
Cable

3-Wire
Cable

Red
Stripe

Red
Stripe

OUT

GND

+12V

OUT

PWR

IR

RCVR

GND

OUT

+12V

7 Foot Quick
Connect Cable

ROOM 4

SMR1

Series

IR Receivers

MR1

Series

Micro IR Receivers

CR1

Connecting
Block

CR1

On-Cabinet
IR Receiver

+12V

OUTPUT
GND

WMR1

Wall Mount
IR Receiver

SMR1P

Surface Mount IR
Receiver w/Mini Plug

CAUTION:

See text, item 5.

WMR1

WALL MOUNT

IR RECEIVER

7 Foot 3-Conductor
Cable with Quick
Connect Stereo Mini Plug

(to other

controlled

devices)

See Item 4

PS1

Power
Supply

CB1

Connecting Block

120 VAC
(Unswitched; see NOTE 1)

EMITTERS

PWR

IR

RCVR

CB1

ONE ZONE

CONNECTING BLOCK

E1

Emitter

E1

Emitter

VE2

Dual

IR Emitter

VE1

IR

Emitter

Satellite Receiver

AV Receiver

DVD

Fig. 2 A Typical

CB1

System

+12 VDC

GND

GND

SIGNAL

470 Ohm resistor

Shielded Cable
to remote room

Ground Shield as shown

CB1 Input

Terminal

Fig. 3: 470 Ohm Capacitance Discharge Resistor (for shielded cable longer than 200 feet.)

Typical Input Terminals of Connecting
Block, Zone Controller, Etc.

33-1892 CB1-inst8-02.qxd 9/23/02 2:27 PM Page 2