Fault Diagnosis

Release 04/02

6-7

Panel PC 670 Computing Unit, Equipment Manual

Error message on screen

Significance/Advice

Operating system not found

Possible causes:
No operating system available
Wrong drive triggered (disk in drive A/B)
Wrong active boot partition
Wrong drive entries in SETUP

Previous boot incomplete
Default configuration used

Termination of the previous boot routine, e.g. through power failure.
Correct entries in SETUP.

System cache error
Cache disabled

Fault in the cache module of the CPU module
Contact your technical service department.

Monitor type does not match
CMOS
Run SETUP

Monitor does not match the SETUP entries.
Adapt the SETUP entries on the monitor.

System timer error

Hardware error
Contact your technical service department.

Real time clock error

Clock module fault
Contact your technical service department.

Keyboard controller error

Keyboard error
Contact your technical service department.