Control elements, Flair, Tube amp – Sound Performance Lab GOLDMIKE MK2 2485 User Manual

Page 13: Goldmike mk2 13

Advertising
background image

GoldMike MK2

13

Flair

As with its predecessor, the model 9844 GoldMike, the
GoldMike MK2 features our sound-optimizing Flair circuitry. This
circuitry takes advantage of a combined coil and tube filtering
to enhance signal presence. In comparison to simple EQ manip-
ulation, this intensified presence sounds very natural and unob-
trusive, and is particularly suited for optimizing the overtones
in voice and acoustic instruments.

Through Flair, a recorded signal gains richness in detail, pres-
ence, intelligibility (for voice) and in an increased ability to cut
through in a mix. In such mixes, a Flair-processed signal stands
out without resort to conventional processing often unsuited to
the task, saving both time and a need for artificial processing.

Flair works through an emphasis in the 1.5-20 kHz range centered
around 6 kHz.

The GoldMike MK2 provides for two different settings, with a
“High” setting of +2.5 dB and a “Med.” with +1.5 dB emphasis.
An Off setting allows you to deactivate the Flair circuit entirely.

Tube Amp

The Tube Amp switch varies the degree of tube pre-amplifica-
tion added to the discrete class A pre-amplification, which
itself is set with the Gain control. The switch allows for three
settings: +6 dB (standard) +12 dB and +18 dB. In each setting,
the output of the tube is automatically reduced in proportion
to the increased input, thus eliminating affects to the overall
output level - there is no need to recalibrate. This allows for
instant comparison between varying Tube Amp values and their
sonic effects (see „About Gain Adjustments” on page 10).

Control Elements

Off

FLAIR

Med

High

12

6

TUBE AMP

18

dB