• 10 •

PROBLEM

REASON

SOLUTION

Inverter does not

turn on.

Poor contact at

terminals

Fuse is blown.

Inverter may be

defective.

Check for poor

connection to battery

or power supply.

Make sure connection

points are clean. Rock

clamps back and forth

for a better connection.
A blown fuse is

usually caused by

reverse polarity or

a short circuit within

the inverter.
To replace, contact

a qualified service

technician who will

diagnose the inverter

and replace the fuse(s)

with the appropriate

replacement(s).
See warranty and call

Customer Service

1-800-621-5485

(Hours 7:00 am to

5:00 pm CST).

SPECIFICATIONS

9.

Model: XI41DU

Maximum Continuous Output .......................................... 410 Watts

Surge Capacity (0.1 second) ........................................... 820 Watts

Optimum Efficiency .................................................................. 85%

No Load Current Draw ........................................................... <0.5A

Output Frequency .........................................................60Hz ± 3Hz

Output Wave Form ...........................................Modified Sine Wave

Input Voltage Range........................................... 10.5V – 15.5V DC

Low Battery Alarm ......................................Audible, 11V ± 0.3V DC

Low Voltage Shutdown...............................Under 10.5V ± 0.3V DC

High Voltage Shutdown ................................Over 15.5V ± 0.5V DC