Sunbeam 2585 User Manual

Page 6

Advertising
background image

Figure 17

NOTE:

An occasional “arcing” sound is normal when operating the unit immediately after

cleaning the cell and

should stop after a few minutes of operation.

TROUBLESHOOTING CHECK LIST

Many times service problems that appear to be major can be solved quite easily. The chart below lists potential problems
and how to correct them. Remember, check the simple things first.

CONDITION

Unit fails

to turn on.

Unit does not
operate at Low speed.

Unit does not
remove pollutants.

Unit sparks,

crackles and pops.

Unit still does not
operate properly.

NOTES:

WHAT TO CHECK

1. Power cord

2. On/Off Switch
3. Cabinet Top is properly

installed.

4. Cell is properly installed.

Setting of On/Off switch

Ionizer-Collector Cell

Ionizer-Collector Cell

Re-check the above points

WHAT TO DO

1. Plug in power cord.

2. Set On/Off switch for desired blower speed.

3. Refer to Item D, Page 4.

4. To properly install the cell, make sure the

side of the cell with three notches at the
bottom is located next to the switch.

Set On/Off switch on High. Run unit for one

minute and reset On/Off switch at Low speed.

Wash ionizer-collector cell by following the
directions listed in “To Clean Cell”. Operate unit
for one week, remove the cell and look at the
cell. If operating correctly, the cell will have a
collection of “adhered pollutants” attached to
the plates of the cell.

Wash ionizer-collector cell. Make sure cell is
thoroughly dry.

Have unit serviced.

1.

Discoloration of aluminum collector cell plates is normal with use, even after cleaning,

2.

Blowing smoke directly into the front grill is not a test for unit performance.

5

Advertising