Preliminary Rev. 0.95

Reset value = 0000 0000

Register 1. Interrupt Status Sticky

Bit

D7

D6

D5

D4

D3

D2

D1

D0

Name

SYS_INIT_STKY LOL_B_STKY LOL_A_STKY LOS_STKY

Type

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

Bit

Name

Function

7

SYS_INIT_STKY System Calibration Status Sticky Bit.

The SYS_INIT_STKY bit is triggered when the SYS_INIT bit (register 0, bit 7) is trig-
gered high. It remains high until cleared. Writing a 0 to this register bit will cause it to
clear.
0: No SYS_INIT interrupt has occurred since it was last cleared.
1: A SYS_INIT interrupt has occurred since it was last cleared.

6

LOL_B_STKY

PLLB Loss Of Lock Status Sticky Bit.

The LOL_B_STKY bit is triggered when the LOL_B bit (register 0, bit 6) is triggered
high. It remains high until cleared. Writing a 0 to this register bit will cause it to clear.
0: No PLL B interrupt has occurred since it was last cleared.
1: A PLL B interrupt has occurred since it was last cleared.

5

LOL_A_STKY

PLLA Loss Of Lock Status Sticky Bit.

The LOL_A_STKY bit is triggered when the LOL_A bit (register 0, bit 5) is triggered
high. It remains high until cleared. Writing a 0 to this register bit will cause it to clear.
0: No PLLA interrupt has occurred since it was last cleared.
1: A PLLA interrupt has occurred since it was last cleared.

4

LOS_STKY

CLKIN Loss Of Signal Sticky Bit (Si5351C Only).

The LOS_STKY bit is triggered when the LOS bit (register 0, bit 4) is triggered high. It
remains high until cleared. Writing a 0 to this register bit will cause it to clear.
0: No LOS interrupt has occurred since it was last cleared.
1: A LOS interrupt has occurred since it was last cleared.

3:0

Reserved

Leave as default.