Mute Control Connections

For mute control, use either a latching switch or a momentary

switch. The total resistance of the cable run from the switch to the

DFR22 should be less than 100 ohms.
Figure 15 shows an example of how to connect either a latching

switch or a momentary switch to the Control Input pins to mute an

input or an output.

Switch

(momentary or latching)

Ground

MUTE CONTROL PIN CONNECTIONS

Figure 15

Gain Control Connections

For gain control, use either a potentiometer or two momentary

switches (one for gain up and one for gain down). If you want to

have multiple sets of gain controls acting on the same inputs or out-

puts, use momentary switches connected in parallel. Figure 16

shows a typical connection between a potentiometer and the Con-

trol Input pins. Figure 17 shows a typical connection between two

momentary switches and the Control Input pins.
When using a potentiometer, the total resistance of the cable run

should be less than 100 ohms.
When using momentary switches, the total resistance of the cable

run should be less than 100 ohms.
NOTE: As supplied, the DFR22 control pins are configured for use

with a 10 Kohm audio taper potentiometer. However, you can use

the Potentiometer Calibration Wizard in the DFR22 software to

configure the DFR22 for use with any 10 Kohm, 20 Kohm, 50

Kohm, or 100 Kohm linear or audio taper potentiometer.

10kW Potentiometer

(Audio Taper)

GAIN CONTROL PIN CONNECTIONS USING A POTENTIOMETER

Figure 16

Switch

(momentary)

Ground

Switch

(momentary)

GAIN CONTROL PIN CONNECTIONS USING SWITCHES

Figure 17

AMX / Crestron Control Connections

You can connect an AMX or Crestron controller to the back panel

RS-232 port, using a Phoenix connector, or to the front panel

RS-232 port, using a DB-9 connector. In either case, you only need

to connect three wires: send, receive, and ground. See page 8 for

the pinout of the RS-232 ports.
To access AMX/Crestron control codes for the DFR22, visit the

DFR22 web page at http://www.shure.com/mixers/models/