Chapter 1

Setting Up the Server Hardware

5

Powering On and Powering Off the
Server Module

You have to apply only standby power to the server module at this point so that you
can perform initial configuration of the service processor (SP). Procedures for
powering on to main power mode and for shutting down from main power mode
are also included in this section.

▼ To Apply Standby Power for Initial Service

Processor Configuration

Use this procedure to apply standby power to the service processor (SP) before initial
configuration.

1. Connect grounded AC power cords to the AC power connectors on the back

panel of the chassis and to grounded AC power outlets. For details, see your
chassis documentation.

In standby power mode, the blue (Ready to Remove) LED is illuminated,
indicating that the SP is working. See

FIGURE 1-2

for the LED location.

Note –

At this point, standby power is supplied only to the service processor and

power supply fans.

2. Continue with initial software setup tasks, as described in Chapter 2 of this

guide.

▼ To Power on Main Power for All Server Module

Components

1. Verify that standby power is on.

In standby power mode, the blue (Ready to Remove) LED is illuminated. See

FIGURE 1-2

.