Installation instructions, Gas requirements – Samsung DC68-02312A-04 User Manual
Page 11

SAMSUNG Dryer Owner’s Instructions A-5
GAS REQUIREMENTS
Use only natural or LP (liquid propane) gases.
THE INSTALLATION MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES,
WITH THE NATIONAL FUEL GAS CODE ANSI/Z223.1, LATEST REVISION (FOR THE UNITED STATES),
OR WITH THE CAN/CGA-B149 INSTALLATION CODES (FOR CANADA).
Gas dryers are equipped with a burner vent for use with natural gas. If you plan to use your dryer with
LP (liquid propane) gas, it must be converted for safe and proper performance by a qualified service
technician.
A 1/2” (1.27 cm) gas supply line is recommended and must be reduced to connect to the 3/8” (1 cm) gas
line on your dryer. The National Fuel Gas Code requires that an accessible, approved manual gas shut-off
valve be installed within 6’ of your dryer.
Gas dryers installed in residential garages must be raised 18 inches (46 cm) above the floor.
Additionally, a 1/8” (0.3 cm) N.P.T. (National Pipe Thread) plugged tapping, accessible for test gauge
connection, must be installed immediately upstream of your dryer’s gas supply connection.
Your dryer must be disconnected from the gas supply pipe system during any pressure testing of the
system.
DO NOT reuse old flexible metal gas lines. Flexible gas lines must be design certified by the American
Gas Association (CGA in Canada).
NOTE :
• Any pipe joint compound used must be resistant to the action of any liquefied petroleum gas.
• As a courtesy, most local gas utilities will inspect a gas appliance installation.
GAS IGNITION – Your dryer uses an automatic ignition system to ignite the burner.
There is no constant burning pilot.
COMMONWEALTH OF MASSACHUSETTS INSTALLATION INSTRUCTIONS
Your dryer must be installed by a licensed plumber or gas fitter. A “T” handle manual gas valve must be
installed in the gas supply line to your dryer. If a flexible gas connector is used to install your dryer, the
connector must have a maximum length of 3’ (36”).
WARNING – Gas leaks may occur in your system, creating a dangerous situation.
Gas leaks may not be detected by smell alone.
Gas suppliers recommend you purchase and install a UL-approved gas detector.
Install and use in accordance with manufacturer’s instructions.
Installation Instructions
- DV317AES-XAA DV3C6BGW-XAA DV316LEW-XAA DV3C6BEW-XAA DV317AEW-XAA DV316BGC-XAA DV316BEC-XAA DV317AGS-XAA DV317AGW-XAA DV316LEW-XAC DV206AES-XAA DV206AGS-XAA DV316BEW-XAA DV316BGW-XAA DV2C6BEW-XAA DV317AGG-XAA DV316LGW-XAA DV316LES-XAA DV316LES-XAC DV306LGW-XAA DV316LGS-XAA DV2C6BGW-XAA DV306LEW-XAA DV317AEG-XAA DV316BEW-XAC