Sun Microsystems Sun Fire X4240 User Manual

Page 77

Advertising
background image

Appendix D

Error Handling

67

Multiple fan
failure

Fan failure is
detected by reading
tach signals.

The Front Fan Fault, Service Action Required,
and individual fan module LEDs are lit.

SP SEL

Fatal

Single power
supply failure

When any of the
AC/DC
PS_VIN_GOOD or
PS_PWR_OK
signals are
deasserted.

Service Action Required, and Power Supply
Fault LEDs are lit.

SP SEL

Non-fatal

DC/DC power
converter
failure

Any
POWER_GOOD
signal is deasserted
from the DC/DC
converters.

The Service Action Required LED is lit, the
system is powered down to standby power
mode, and the Power LED enters standby
blink state.

SP SEL

Fatal

Voltage
above/below
threshold

The SP monitors
system voltages and
detects voltage
above or below a
given threshold.

The Service Action Required LED and Power
Supply Fault LED blink.

SP SEL

Fatal

High
temperature

The SP monitors
CPU and system
temperatures, and
detects
temperatures above
a given threshold.

The Service Action Required LED and System
Overheat Fault LED blink. The motherboard
is shut down above the specified critical level.

SP SEL

Fatal

Processor
thermal trip

The CPU drives the
THERMTRIP_L
signal upon
detecting an
overtemp condition.

CPLD shuts down power to the CPU. The
Service Action Required LED and System
Overheat Fault LED blink.

SP SEL

Fatal

Boot device
failure

The BIOS is not able
to boot from a
device in the boot
device list.

The BIOS goes to the next boot device in the
list. If all devices in the list fail, an error
message is displayed, retry from beginning of
list. SP can control/change boot order.

DMI Log

Non-fatal

TABLE D-1

Hardware Error Handling Summary (Continued)

Error

Description

Handling

Logged (DMI
Log or SP
SEL)

Fatal?

Advertising