Additional Equipments

Ward Control Unit (WCU): When fitted the WCU will allow

a group of circuits, which are designated a Ward, to be

Set and Unset using Exit and Entry routes separate from

the system. The WCU is connected to the outputs and

circuits of a REM or a NU and will require a separate 12V

supply.
Printer: An Epson printer P40-S may be connected

temporarily to the CP or to the SlB to provide printout

records. Other printers that accept RS232 serial data

may be permanently connected to the SIB if permanent

records are required.
Power Supply Unit: All power can be supplied from the

TS2000 CP internal Power Supply Unit but in large systems

it may be necessary to fit additional power supply units.

The PSU150 has been designed for use with the TS2000

system and consists of a PSU and battery (supplied

separately) and it may also have a Node Unit and a

Relay Unit fitted in its enclosure.
Output Modules (OM): If remote indicators or Mimic

Panels containing LEDs are required then Output

Modules type CPA6.OM may be connected to the CP.

Each OM unit will drive up to eight LEDs and the units may

be interconnected for large displays. The system may

be programmed so that the LEDs indicate circuit

condition or alarms and ward status if wards are

programmed.
Extension loudspeakers: The REM contain a small

sounder unit to provide an indication of the system

status. If the volume of the sounder is insufficient (e.g. a

louder exit sound is required) then an extension speaker

may be fitted to the NU and this will require a

Loudspeaker Drive Unit type LSD1 to be connected

between the NU and the loudspeaker. A separate 12V

power supply will also be required.
Relay Unit: The NU and REM programmable outputs will

provide current limited drive for various facilities but in

many cases it will be necessary to isolate the system

from the external equipment by driving via relays. Relay

Units type RM3A provide two relays, which may be

energised by NU or REM programmable outputs, and

which provide two sets of ’clean’ change over contacts.

The unit may be fitted separately or in a PSU150 case.

Remote Data Transfer

When fitted with a Digimodem type DC3M the system

may be programmed from a remote location, and log

data transferred to it, using a dedicated program

installed in a Personal Computer at that location. The

use of this facility is protected by a series of passcodes

and user menus.

496529 Issue A