Fireplace framing specifications, Figure 9 figure 10 – Superior DT-400CMP User Manual

Page 7

Advertising
background image

7

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

*34

⁵⁄₁₆

(872)

Back wall of chase/enclosure (including any finishing materials)

a

8

³⁄₁₆ (208)

b

Note-
Venting requirements for rear vent applications in corner installations -
- the round termination (SV4.5HTR) may not be used
- the horizontal vent length “a” to “b,” must not exceed 28 inches (711 mm)

*17

³⁄₁₆

(437)

Inches

(millimeters)

*These dimensions occur when one 45

degree elbow is connected directly to the

appliance collar and the unit moved

¹⁄₂ in.

(13 mm) into the room. This

¹⁄₂ in.

movement is required to achieve a min. of

5 in (127 mm) in the F dimension.

*F = 5 in.

(127 mm)

*24

¹⁄₄

(616)

33

¹⁄₈

(841)

*48

¹⁄₂

(1232)

CORNER FRAMING WITH SQUARE HORIZONTAL

TERMINATIONS (SV4.5HTSSL, SV4.5HTSS or SV4.5HTS)

SV4.5HTSS & SV4.5HTSSL

Termination

Framing should be constructed of

2x4 or larger lumber.

7 (178)

b

SV4.5HTS Termination

7

(178)

5

¹⁄₈

12

¹⁄₈

(308)

10

¹⁄₂

(

267

)

VENT FRAMING -
TOP VENT WITH ONE

90

°

ELBOW

VENT FRAMING -
REAR VENT WITH
NO ELBOWS

Framing should be constructed of
2x4 or larger lumber.

Inches (mm)

(130)

5

¹⁄₈

(130)

7

(308)

12

¹⁄₈

(178)

*12

⁷⁄₈ inches (327 mm)

is the required

framing depth dimension when the finish

material (drywall) thickness is 1/2 in.

(13mm).

*12

⁷⁄₈

(327)

33

¹⁄₄

(845)

33

¹⁄₄

(845)

16

⁵⁄₈

(422)

37

¹⁄₈

(943)

19

⁵⁄₈

(498)

**FRAMING WITH SQUARE HORIZONTAL TERMINATIONS (SV4.5HTSSL, SV4.5HTSS or SV4.5HTS)

AND ROUND HORIZONTAL TERMINATION (SV4.5HTR)

** See the horizontal venting Figures 35
and 36 on page 16 for restrictions on the

use of the round termination (SV4.5HTR)

Figure 9

Figure 10

FIREPLACE FRAMING SPECIFICATIONS