Electrical, Extension cords 220v operation, Electrical specifications – Woodstock SHOP FOX W1808 User Manual

Page 15

Advertising
background image

-13-

W1808/W1809/W1810 Cyclone Dust Collectors

EL

EC

TR

IC

A

L

ELECTRICAL

DO NOT work on your electrical system

if you are unsure about electrical

codes and wiring! Seek assistance from

a qualified electrician. Ignoring this

warning can cause electrocution, fire,

or machine damage.

We do not recommend using an extension cord; however,

if you have no alternative, use the following guidelines:

• Use a cord rated for Standard Service (S).

• Do not use a cord longer than 50 feet.

• Ensure that the cord has a ground wire and pin.

• Use the gauge size listed below as a minimum.

Extension Cords

220V Operation

The Model W1808/W1809/W1810 is wired for 220V single-

phase operation. Always connect this machine to a dedi-

cated circuit (wire, breaker, plug, receptacle) with a

verified ground, using the recommended circuit size and

plugs/receptacles listed at the bottom of this page.

Never replace a circuit breaker with one of higher

amperage without consulting a qualified electrician to

ensure compliance with wiring codes.

This machine must be grounded! Verify the ground before

connecting this machine to the power source.

If you are unsure about the wiring codes in your area

or you plan to connect your machine to a shared cir-

cuit, you may create a fire or circuit overload hazard—

consult a qualified electrician to reduce this risk.

Model

Operating Voltage Amp Draw Min. Circuit Size

Plug/Receptacle

Extension Cord

W1808

220V

14 Amps

20A

NEMA L6-20

14 Gauge

W1809

220V

22 Amps

30A

NEMA L6-30

10 Gauge

W1810

220V

22.4 Amps

30A

NEMA L6-30

10 Gauge

Figure 2. L6-20 and L6-30 plug and

receptacle.

L6-30 P

L6-30 R

Electrical Specifications

L6-20 P

L6-20 R

Advertising
This manual is related to the following products: