7-8

ROUTING SWITCHER SYSTEM (E)

V : DISPLAY UNIT STATUS (HDS-X3000 Series)

Purpose

Purpose is to display the internal status of the equipment.
There are no setting on this screen.

Press [Ctrl]

_ [E] to return to the menu screen of the

secondary station.

Example of Display Screen (HDS-X3400)

Example of Display Screen (HDS-X3600)

DISPLAY UNIT STATUS HDS-X3400 V1.00 STATION NUMBER 1

INPUT

01-16

MAIN

HD SDI

REVŁ

1.0

REVŁ

1.0

P.S

OK

CN 01-16

HD SDI

OUTPUT

01-16

MAIN

HD SDI

REVŁ

1.0

REVŁ

1.0

P.S

OK

CN 01-16

HD SDI

FRONT PANEL BKS-R3400

CONTROL BOARD REFERENCE SIGNAL 1125p

MAIN S-BUS SELECT FIELD FIELD

V1.00 V1.00 POWER SUPPLIES ON

FAN1 FAN2

ROT ROT

Ctrl-E:RETURN TO MENU

DISPLAY UNIT STATUS HDS-X3600 V1.00 STATION NUMBER 1

INPUT

01-32Ł

33-64

MAIN

HD SDI

HD SDI

REVŁ

1.0

1.0

CN01-16

HD SDI

HD 0pt16

REVŁ

1.0

1.0

CN17-32

HD SDI

HD SDI

REVŁ

1.0

1.0

P.S

OK

OK

MAIN

HD SDI

HD SDI

REVŁ

1.0

1.0

CN01-16

HD SDI

HD 0pt16

REVŁ

1.0

1.0

CN17-32

HD SDI

HD SDI

REVŁ

1.0

1.0

P.S

OK

OK

REF

A

B

FANA

ROT

ROT

FANB

ROT

ROT

OUTPUT

01-32Ł

33-64

A B

CONTROL BOARD REFERENCE SIGNAL 1125p 625

MAIN S-BUS MONITOR SELECT FIELD FIELD ODD

M V1.00 V1.00 V1.00 POWER SUPPLIES ON INVALID

B INVALID

FAN1 FAN2

ROT ROT

Ctrl-E:RETURN TO MENU

DISPLAY UNIT STATUS HDS-X3700 V1.00 STATION NUMBER 1

INPUT

01-32Ł

33-64

65-96Ł

97-128

MAIN

HD SDI

HD SDI

HD SDI

INVALID

REVŁ

1.0

1.0Ł

1.0

CN01-16

HD SDI

HD 0pt16

SD SDI

INVALID

REVŁ

1.0

1.0

1.0

CN17-32

HD SDI

HD SDI

SD SDI

INVALID

REVŁ

1.0

1.0Ł

1.0

P.S

OK

OK

OK

MAIN

HD SDI

HD SDI

HD SDI

INVALID

REVŁ

1.0

1.0Ł

1.0

CN01-16

HD SDI

HD 0pt16

SD SDI

INVALID

REVŁ

1.0

1.0

1.0

CN17-32

HD SDI

HD SDI

SD SDI

INVALID

REVŁ

1.0

1.0

1.0

P.S

OK

OK

OK

REF

A

B

A

FANA

ROT

ROT

ROT

ROT

FANB

ROT

ROT

ROT

ROT

OUTPUT

01-32Ł

33-64Ł

65-96Ł

97-128

A B

CONTROL BOARD REFERENCE SIGNAL 1125p 625

MAIN S-BUS MONITOR SELECT FIELD FIELD ODD

M V1.00 V1.00 V1.00 POWER SUPPLIES ON INVALID

B INVALID

FAN1 FAN2 FAN3 FAN4 FAN5 FAN6

ROT ROT ROT ROT ROT ROT

Ctrl-E:RETURN TO MENU

Example of Display Screen (HDS-X3700)

Description of contents on display
MAIN or CN01-16/CN17-32

: HD SDI/SD SDI/HD 0pt8/

INVALID
Displays whether the board (MAIN) to be inserted from

the front and the rear connector board (CN01-16/CN17-
32), are inserted or not.

P.S

: OK/NG

Displays the power supply status of the MAIN and two CN boards.

REV

: REVISION of the boards

REF

: A/B

Displays which of the two types of the reference signal is selected.

REFERENCE SIGNAL

: 525i/625i/1125i

Displays the number of lines of the detected reference signal.

SELECT FIELD

: ASYNC/ODD/EVEN/FIELD/(ASYNC)

Displays the switching timing of the matrix.

POWER SUPPLIEDS

: ON/INVALID/OVERLOAD

Displays the status of the power supply unit. When
OVERLOAD is displayed as this status, it means that the

excess number of rear optical connectors more than the
specified number are installed.