ENGLISH

Drain Hose

Connecting the pipe

Drilling a Hole in the Wall

Drill a hole of 60mm(2 ") in diameter to the outside.

The drilling should be done at a distance of less than
150mm(5 ") from the floor facing the indoor unit.

Extend the drain hose to the drain hose connected to
the drain pan, and fix it with the tape or a cable tie to
prevent separation. Then make a covering of it so
that water cannot flow outwardly.

The piping of this unit can be connected to the right, left, or
rear side. When you hit the area for piping connection slightly
with a hammer, a hole is made.

CAUTION

1. As the draining is of natural drain type, make the drain hose direct

downward.

2. If there is any foreign substance in the drain plate, it may clog the

drain pipe. Therefore, be sure to remove the foreign substance
inside after installation.

3. After completion of installation, be sure to pour water into the drain

pan, and then check the draining condition.

(There is no problem in draining when the draining is completed

within 20 seconds.)

Less than
150mm

(5 )

8

7"

60mm

(2 )

8

3"

Foamed Polyethylene

Insulator

Vinyl Chloride(Inner diameter ø 18mm ")

Outer diameter ø 23mm ")

Piping Material

Holes for piping
connection (3 points)

3

8

7

8

7

8

11

16