4-1.

PRECAUTIONS FOR USE OF TEST MODE

• As loading related operations will be performed regardless of the test mode operations being performed, be sure to check that the disc

is stopped before setting and removing it.
Even if the

Z

button is pressed while the disc is rotating during continuous playback, continuous recording, etc., the disc will not stop

rotating.
Therefore, it will be ejected while rotating.
Be sure to press the

Z

button after pressing the

[MENU/NO]

button and the rotation of disc is stopped.

4-1-1. Recording laser emission mode and operating buttons

• Continuous recording mode (CREC 1MODE)
• Laser power check mode (LDPWR CHECK)
• Laser power adjustment mode (LDPWR ADJUST)
• Comparison with initial Iop value written in nonvolatile memory (Iop Compare)
• Write current Iop value in read nonvolatile memory using microprocessor (Iop NV Save)
• Traverse (MO) check (EF MO CHECK)
• Traverse (MO) adjustment (EF MO ADJUST)
• When pressing the

z

button.

4-2.

SETTING THE TEST MODE

The following are two methods of entering the test mode.
Procedure 1: While pressing the

[ AMS ]

knob and

x

button simultaneously, connect the power plug to the outlet, and release

the

[ AMS ]

knob and

x

button.

When the test mode is set, “[Check]” will be displayed. Turning the

[ AMS ]

knob between the following three

groups; ···Tt [Check] Tt [Service] Tt [Develop] Tt ···.

Procedure 2: While pressing the

[ AMS ]

knob, connect the power plug to the outlet, and release the

[ AMS ]

knob.

When the test mode is set, “TEMP CHECK” (C12) will be displayed. By setting the test mode using this method, only the
“Check” group of procedure1 can be executed.

Note:

Do not use the test mode in the [Develop] group.
If used, the unit may not operate normally.
If the [Develop] group is set accidentally, press the

[MENU/NO]

button immediately to release the [Develop] group.

4-3.

RELEASING THE TEST MODE

Press the

I/1

button. The unit sets into the STANDBY state, and the test mode ends.

4-4.

BASIC OPERATIONS OF THE TEST MODE

All operations are performed using the

[ AMS ]

knob,

[YES]

button, and [MENU/NO] button.

The functions of knob and buttons are as follows.

Function name

Function

[ AMS ]

knob

Changes parameters and modes

[YES]

button

Proceeds onto the next step. Finalizes input

[MENU/NO]

button

Returns to previous step. Stops operations

. >

. >

. >

. >

. >

. >

. >