Telephone connection, Telephone numbers, Identification code – Siemens IC60 User Manual

Page 3: Testing installation

Advertising
background image

Siemens Building Technologies

Fire Safety & Security Products

01.2008


t the keypad will start beeping to indicate

that learn mode has been activated.

2. Press the ARM button

on the remote

control

t it will send a transmission signal. The

panel will confirm if a user is found with
the message “Found”.

3. Press

to confirm.

4. Repeat the actions 1 - 3 to follow up for all

5 buttons (use the navigation button to
switch to the next user number).

For remote control 2 take user numbers 26 -
30 etc.

Telephone connection

To transmit events, the system needs to be
connected to a telephone line. Follow steps
8 - 9 to program the telephone numbers.
If no telephone line is connected, the dialer
must be turned off:

1. Press

175

1

t the display shows:

“Dialer A Option 12----7-“.

2. Press 1

t the display shows: “-2----7-“.

3. To check: press

Ctrl

simultaneously

t the display changes to clear text mode

and shows “Enable Dialer No”.

4. Press

to go back and continue with

step 10 “Testing Installation”.

Telephone numbers

The telephone numbers (max. 8) which are
dialed in case of an event can be up to
16 digits long. Default setting: Telephone
number 8 is the call back number of the
Control Monitoring Station (CMS).
1. Telephone number 1:

press

181

1

“tel.number”

2. Choose a reporting format for this number.
a) Number related to a phone:

press

182

1

2

t an alarm signal will be sent out to this

number when an event occurs.

b) Call goes out to a CMS station:

CID format: press

182

1

1

SIA format: press

182

1

10

3. Repeat actions 1 - 2 to follow up for

telephone numbers 2 - 8 (use the naviga-

tion button to switch to the next tele-
phone number).

There are 11 different reporting formats that
can be selected for each telephone number.
The formats are listed in the Installer Manual.

Identification code

When connected to a monitoring station you
can program an individually identification
code:
Area A: press

62

1

”code”

(4 digit code 0-F).

Testing Installation

To test the strength of the signal received on
the panel: press

200

14

Any time a signal is detected, the keypad
beeps and displays the received signal
strength in % for 30 sec.
To test all detectors on their function and
transmission range, change to walk test
mode.

In the walk test mode the panel will not

send out any alarms and the working
range will be less than in the normal op-
erating mode - EN50131 requirement.

1. Start walk test: press

200

6

t the keypad will start beeping to indicate

that walk test mode has been activated.

2. Activate the installed detectors with a

magnet

t it will send a transmission signal (for more

details see Installation Instruction of the
detector). The panel will give a notification
signal each time a detector signal is re-
ceived and will show the detector number
on the display.

3. To end this mode: press

.

t this will take you back to the normal mode.
4. To check out all received signals in event

log: press

.

5. To clear events in the log: press

or

enter the installer code (see User Manual
3.15.3).

The programming is finished now and the
system ready to operate.
Don’t forget to reconnect the internal siren!


Advertising