Trident protection circuitry, Trouble shooting – Soundstream Technologies HRU. 2 User Manual

Page 16

Advertising
background image

16

TRIDENT PROTECTION CIRCUITRY

Your

Human Reign Unleashed

amplifier is protected against both overheating

and short circuits by means of main power fuses and the following circuits:

Speaker Output Protection
Ground Fault Differential
Smart Power Supply Thermal Rollback & Thermal Protection Circuit

TROUBLE SHOOTING

PROBLEM

CAUSE

No Sound and power LED is not

lit

1. No power or ground at the

amp

2. No remote turn-on signal

3. Blown fuse near the battery

No Sound , power LED is lit

No signal input

Repeatedly blow amp fuse;

frequent activation of Smart

Power Supply Circuit

1. Speaker or leads may be

shorted

2. Verify adequate amp

ventilation.

Distorted output

Output signal level is too high and

the amplifier output is clipping.

Reduce the level either at the

source or at the input level

controls.

NOTE: If you experience blown main power supply fuses, it is likely that the

amplifier is seeing a dead short, either in the speaker wire or in the speaker

itself. Rectify the problem before blowing multiple fuses!

DO NOT increase values beyond the original fuse value! Doing so will void

your warranty and may damage your amplifier