TROUBLESHOOTING

4.1 LIGHT INDICATORS

The freezer has two lights that will alert the user if a problem occurs: an ADD MIX light and a Diagnostic Light.

The ADD MIX light will flash to alert the operator to a low mix condition. It does so by monitoring the mix level in the
hopper. When the ADD MIX light is flashing, refill hopper immediately.

The Diagnostic Light will flash if an error occurs. Refer to the chart below for details.

4.2 TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

REMEDY

Freezer does not
run.

1. Power to freezer is off.
2. Blown fuse or tripped circuit.
3. Freeze-up (auger will not turn).

4. High pressure cut-out tripped.
5. Front door not in place.

1. Supply power to freezer.
2. Replace or reset.
3. Turn CLEAN-OFF-ON switch to OFF (middle)
position for 15 minutes, then restart.
4. Wait until automatic reset for freezer to start.
5. Assemble front door in place.

Freezer will not
shut off.

1. Drive belt failure.
2. Consistency temperature setting is too
firm.
3. Refrigeration problem.

1. Replace drive belt.
2. Turn Consistency Adjustment knob counter-
clockwise.
3. Check system. (Call distributor for service)

Product is too firm.

1. Consistency temperature setting is too
firm.

1. Turn Consistency Adjustment knob counter-
clockwise.

Indication

On

One Blink

Two Blinks

Three Blinks

Conditions

Defrost Mode

Torque is not

met after 20

minutes

(22 minutes for

shake)

Drive current is not sensed

Freezer left in clean

mode for over 20

minutes

Self
Correction

N/A

N/A

The freezer attempts to sense drive

current with a 3 second pre-stir. If current

is sensed, the freezer will return to normal

operation. If current is not sensed, the

freezer will wait 7 minutes and try to

sense current with another 3 second pre-

stir. After the third attempt, the

compressor will run on timers.

N/A

Operation

Every 7 minutes

the auger will

run for 90
seconds.

Timers

Timers

Off

Corrective
Action

N/A

Contact Service

Technician

Contact Service Technician

Turn CLEAN-OFF-ON

switch to OFF

(middle) position then

turn the switch to ON.

Advertising