Sy-5ema+ v1.x quick start guide 11 installation – SOYO Super 7 SY-5EMA User Manual

Page 11

Advertising
background image

SY-5EMA+ V1.x Quick Start Guide

11

Installation

Frequency Setting: SW1

Processor

Multiplier

CPU

Bus

Clock

JP10

JP8

JP9

1

2

3

4

5

6

2.5x

66MHz

1-2

2-3

2-3

on

on off off off off

Cyrix 6x86 MX PR 200

2.0x

75MHz

1-2

2-3

2-3

on off off off on off

Cyrix 6x86 MX PR 233

2.5x

75MHz

1-2

2-3

2-3

on

on off off on off

Cyrix 6x86 MX PR 266

2.5x

83MHz

1-2

1-2

2-3

on

on off on on off

3.5x

66MHz

1-2

2-3

2-3

off off off off off off

Cyrix MII 300

3x

75MHz

1-2

2-3

2-3

off on off off on off

4.0x

66MHz

1-2

2-3

2-3

on off on off off off

3.5x

75MHz

1-2

2-3

2-3

off off off off on off

Cyrix MII 333

3x

83MHz

1-2

1-2

2-3

off on off on on off

Cyrix MII 366

2.5x

100MHz

1-2

1-2

2-3

on

on off off off on

Cyrix MII 400

3x

95MHz

1-2

1-2

2-3

off on off on off on

Cyrix MII 433

3x

100MHz

1-2

1-2

2-3

off on off off off on

P54C P100

1.5x

66MHz

1-2

2-3

2-3

off off off off off off

P54C P133

2.0x

66MHz

1-2

2-3

2-3

on off off off off off

P54C/P55C P166

2.5x

66MHz

1-2

2-3

2-3

on

on off off off off

P54C/P55C P200

3x

66MHz

1-2

2-3

2-3

off on off off off off

P55C P233

3.5x

66MHz

1-2

2-3

2-3

off off off off off off

IDT X86 CPU C6/2-
200

3x

66MHz

1-2

2-3

2-3

off on off off off off

IDT X86 CPU C6/2-
225

3x

75MHz

1-2

2-3

2-3

off on off off on off

IDT X86 CPU 2-233

3.5x

66MHz

1-2

2-3

2-3

off off off off off off

IDT X86 CPU 2-266

2.33x

100MHz

1-2

1-2

2-3

off on

on off off on

IDT X86 CPU 2-300

2.5x

100MHz

1-2

1-2

2-3

on on off off off on

3x

66MHz

1-2

2-3

2-3

off on off off off off

Rise mP6 PR266

2x

100MHz

1-2

1-2

2-3

on off off off off on

This main board supports various CPU multiplier and host bus frequency settings.

*Please select the proper frequency setting based on specifications of the CPU you have
purchased. System stability or components damage, in case of over-specification setting, is
not guaranteed.

*

The K6-2 300 and 333 come in several versions with different host bus frequency

specifications. Please verify the correct host bus frequency settings before installation.

Advertising