1 adjustment of minimum for natural gas, 2 regulation of minimum for lpg, 3 positioning and levelling of the appliance – Smeg A11A-6 User Manual
Page 11: Final operations, Instructions for the installer
 
Instructions for the installer
4. FINAL OPERATIONS
After replacing the nozzles, reposition the flame-spreader crowns, the 
burner caps and the grids. 
After adjustment to a different kind of gas from the one for which the
cooker has been tested, replace the plate inside the storage
compartment with one corresponding to the new kind of gas. This plate
can be obtained from your nearest Authorised Assistance Centre.
4.1 Adjustment of minimum for natural gas
Light the burner and take it to the minimum. 
Remove the gas tap knob and turn the 
adjustment screw inside or at the side of the tap 
shaft (depending on the model) until there is a 
regular minimum flame. Replace the knob and 
check burner flame stability: (rapidly turning the 
knob from maximum to minimum position, the 
flame should not go out). Repeat the operation on 
all the gas taps. 
4.2 Regulation of minimum for LPG
For regulating the minimum with LPG, the screw at the side of the tap rod 
must be turned clockwise all the way. 
The bypass diameters for each individual burner are shown in paragraph 
“3.2 Burner and nozzle characteristics table”. Once the regulation has 
been completed, replace the seal on the by-passes using paint or similar 
materials. 
 
4.3 Positioning and levelling of the appliance
Having carried out the electricity and gas hook-up, level the appliance 
using the four adjustable legs. 
13