15-51

Chapter 15: Appendix

15

(6) Installation of terminators (terminating resistors)

Insulation on connectors and terminators
Shown below is a method for insulating a relay connector and an "L" type connector.

Insulating a relay connector

Insulating an L type connector

The method for insulating a terminator (T-NP male and T-NJ female) is as follows.
- Cover the insulation sleeve (black) (I-NPC) to the male T-NP.
- Cover an insulation sleeve (black) (I-NJP) to the female T-NJ.

Coaxial connector
(type N)

Insulation tape

Straight sleeve

Insulation sleeve cut away

Insulation sleeve

Coaxial cable

Coaxial connector (type N)

Insulation tape

L type connector

Insulation sleeve cut away

Transceiver NJ connector