Chapter 12: Parameters

12

Chapter 12: Parameters

This chapter describes the parameters that can be set in the module. The parameter area is set in the
control module (CPU board).

"12-3 How to set parameters."

12-1 Table of parameters

Address

(8)

Details

Reference

page

00

IP address

When FF

(H)

is written to address 03, the module will

enter the data memory setting mode.
- Enter the parameter file address at addresses

00 and 01. Enter the file number at address 02.

7-5
7-8

12-3

15-13

01

IP address

02

IP address

03

IP address, node number

04

Token monitor timing => See next page

8-13

05

Interval between frames (normally set to 0)

15-22

06 to 07

Reserved area

-

10

Data transmission Area 1 top address (word address) for this node.

- Address 10 is for the lower digit. Address 11 is for the upper digit.

Related to

cyclic
transfers

Chapter 8

11

12

Data length (word) of Area 1 for this node.

- Address 12 is for the lower digit. Address 13 is for the upper digit.

13

14

Data transmission Area 2 top address (word address) for this node.

- Address 14 is for the lower digit. Address 15 is for the upper digit.

15

16

Data length (word) of Area 2 for this node.

- Address 16 is for the lower digit. Address 17 is for the upper digit.

17

20

Top address of Area 1 on the PC (word address)
- Address 20 is for the lower digit. Address 21 is for the upper digit.

21

22

Area 1 file number on the PC

23

Reserved area

24

Top address of Area 2 on the PC (word address)
- Address 24 is for the lower digit. Address 25 is for the upper digit.

25

26

Area 2 file number on the PC

27

Reserved area

-

30

Top address of the communication control area on the PC (word
address)
- Address 30 is for the lower digit. Address 31 is for the upper digit.

Related to

communi-
cation
control

Chapter 10

31

32

Communication control area's file number on the PC

33

Communication control area transfer type
- Specify the address to transfer from the module to the control

module (CPU board)

00

(H)

: Transfer all of the area

80

(H)

: Does not transfer data from the communication transfer area.

81

(H)

: Transfer only the participating node list flag, operation status

flag, and error status flag.

83

(H)

: Transfer all of the area.

34

Transmission buffer top address (word address)
- Address 34 is for the lower digit. Address 35 is for the upper digit.

Related to
message

transfer

Chapter 9

35

36

Transmission buffer file number

37

Enable/disable use of the transmission buffer => See next page

40 to 51

Node name (10 ASCII characters)

-

52 to 57

Reserved area

-

60

Timeout time for the SEND/RECEIVE instruction (0.1 to 25.5 sec.).

11-8

61 to 76

Reserved area

-

77

Start switch
- When the value of this switch changes from 00 to 01

(H)

, the parameters

settings are transferred to the module.

8-3
9-2

- Do not write data in the reserved areas (5 locations).

When the JW-50FL is used, set the parameters in system memory.

See pages 12-4 to 12-5.