Unstable) -3 – Sharp Z-336J User Manual

Page 146

Advertising
background image

13-3

Chapter 13: Troubleshooting

13

[2] Problems concerning the network and appropriate countermeasures (when

communications are unstable)

Symptom

Check points

Check details

Countermeasures

Unable to

communicate,
or unstable
communication

Communication
route

Make sure the external conductive

shields of all the coaxial cables are
connected to ground at one point

Ground properly, according

to section 15-6.

Are the shield wires of the AUI
cables properly connected to
ground?

Ground according to the
manufacturer's instruction
manuals

Does each station respond properly

to a Ping command?

Check the power and
cables of any station that
doesn't respond properly.

Is the collision lamp lit frequently?

Check the contacts in
cables and connectors.
Check for abnormalities
using an analyzer.

Are repeaters used in less than 4

layers

Review the configuration

according to section 15-6.

Is each segment within the

maximum length?

Are termination resistors installed at

both ends?

Is the number of devices connected

in each segment within the specified
range?

Are 3 or fewer segments used to
connect the equipment?

Is power to the repeaters turned on?

Check the power supply
and power cable, as well
as the voltage.

Participating

stations
equipment
settings

Are the IP addresses for the network
set properly?

Check the IP addresses
and support tools using an
analyzer.

Are the station numbers of the
equipment set properly?

Check the IP addresses
and support tools using an
analyzer.

Are the equipment parameters set

properly?

Check the equipment
parameters using support

tools.

Are the CD (carrier detection)

indicators lit consecutively or
intermittently?

Check the communication
cables, and the AUI power
supply.

Are the SD (send) indicators lit
consecutively or intermittently?

Re-check the equipment

settings.

Are the LK (link) indicators lit
consecutively?

Re-check the equipment

parameter settings

Advertising