3 z-336j, 3 z-336j -3 – Sharp Z-336J User Manual

Page 16

Advertising
background image

4-3

Chapter 4: Name and Function of Each Part

4

4-3 Z-336J

1

Display panel

2

Connector for programmer

4

Connector for 10BASE5

6

12 VDC power supply input terminal

8

Reset switch

7

Module No. switch SW4

(Factory setting: 0)

9

Switch SWA

0

Switch SW1

5

Switch SW6

3

Connector for 10BASE-T

(Factory setting: ON)

Factory setting
: ON

Factory setting
: ON

Name

Function

1

Display panel

Displays this board operating status using LEDs.

LN

Lights when communicating normally.

TX

Blink at transmitting data.

RX

Blink at receiving data.

12 V

Lights when 12 VDC is supplied. (Only when 10BASE5 is used.)

T

Lights at test mode. (Normally, this is not used.)

PE

Lights at parameter setting error.

HE

Lights at this board error.

S0 to S7

Displays the station number when operating normally. Displays an error

code if an error occurs.

2

Connector for programmer

Connect a JW-14PG programmer or similar equipment to set the
parameters on this board.

3

Connector for 10BASE-T

Connect the 10BASE-T coaxial cable.

4

Connector for 10BASE5

Connect the 10BASE5 coaxial cable.

Make sure to slide the lock securely to the "lock" position.

5

Switch SW6

ON

The shield on the cable between a 10BASE-T connector and a

10BASE5 connector and the FG (base) on this module will be shorted

together.

OFF

The shield on the cable between a 10BASE-T connector and a

10BASE5 connector is not shorted to the base.

- Ground the FG line on the 12 VDC connector separately.

6

12 VDC power supply

input terminal

When 10BASE5 is used, connect a commercially available DC power
supply that is designed to supply power to transceivers. The DC power
supply must provide 12VDC ±5% and 0.5 A or more.

7

Module No. switch

Specify a module number from 0 to 6.
- Be careful do not use the same number for another option board.

8

Reset switch

Only used by SHARP engineers. Users should not press this switch.

9

Number of communication
boards

Switch SWA

Specify the number of communication boards actually installed
(including the Z-336J).

-

See pages 5-3 to 5-7.

0

Switch SW1

No need to set this switch for the Z-336J. (Always set to OFF (default).)