Storage instructions, Service air cleaner, Clean spark arrester screen – Snapper 1666-0 User Manual

Page 12: Transporting and storage

Advertising
background image

• Reinstall spark plug.

Service Air Cleaner

Your engine will not run properly and may be damaged if
you run it using a dirty air filter element.

Check the air filter every use and clean or replace the air
filter element every 50 hours of operation or every three
months, whichever comes first. Clean or replace more
often if operating under dusty or dirty conditions.

To clean or replace air filter element:

• Loosen the air cleaner cover screws, remove the air

cleaner cover, and remove the element (see page 20).

• Wipe clean the inside of the filter housing and cover

thoroughly.

• Wash the element in a solution of household detergent

and warm water, then rinse thoroughly. Or wash in
nonflammable or high flash point solvent. Allow the
element to dry thoroughly.

• Soak the element in clean engine oil and squeeze out the

excess oil. Do Not twist. The engine will smoke during
initial start-up if too much oil is left in the element.

NOTE: If you need to order a new air filter element,
please contact the local dealer.

• Reinstall the air cleaner element and the cover. Hand

tighten the air cleaner cover screws.

Clean Spark Arrester Screen

The engine muffler is equipped with a removable spark
arrester screen. Inspect and clean the screen every
10 hours of operation or every three months, as shown in
Figure 14:

• Loosen the screw on the muffler and remove the spark

arrester screen.

• Use a brass or stiff-bristle brush to remove carbon

deposits from the spark arrester surface.

• Inspect the spark arrester for breaks or tears and

replace it if necessary.

NOTE: If you need to order a new spark arrester, please
contact the local dealer.

• Install the clean screen in the reverse order of removal.

NOTE: If you use your generator on any forest-covered,
brush-covered or grass-covered unimproved land, it must
have a spark arrester installed. The spark arrester must be
maintained in good condition by the owner/operator.

STORAGE INSTRUCTIONS

Transporting and Storage

When transporting the generator, turn the engine switch
to “Off” and the fuel valve to “Close”. Keep the generator
level to prevent fuel spillage.

WARNING!

Contact with a hot engine or

exhaust system can cause serious burns or fires. Let
the engine cool before transporting or storing the
generator.
Take care to not drop or strike the generator when
transporting. Do Not place heavy objects on the
generator.

The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than 30 days,
use the following guidelines to prepare it for storage.

12

Snapper G1000 Generator

Figure 13 — Service Spark Plug

Spark Arrester

Screen

Muffler

Spark Arrester

Attachment Screw

Figure 14 – Service Spark Arrester Screen

Advertising