Rs-232c port specifications – Sharp Aquos LC 30HV2U User Manual

Page 73

Advertising
background image

72

RS-232C port specifications

Return code

Command 4-digits

Parameter 4-digits

Computer Control of the Display

• When a program is set, the Display can be controlled from the computer using the RS-232C terminal.

The input signal (computer/video) can be selected, the volume can be adjusted and various other adjustments
and settings can be made, enabling automatic programmed playing.

Attach an RS-232C cable cross-type (commercially available) to the supplied Din-D/sub RS-232C for the

connections.

A
• This operation system should be used by a person who is accustomed to using computers.

Communication conditions
Set the RS-232C communications settings on the computer to match the display’s communications conditions.
The display’s communications settings are as follows:

Baud rate:

Parity bit:

Data length:

Stop bit:

Flow control:

9,600 bps

8 bits
None

1 bit

None

Appendix

Command format

Communication procedure
Send the control commands from the computer via the RS-232C connector.
The display operates according to the received command and sends a response message to the computer.
Do not send multiple commands at the same time. Wait until the computer receives the OK response before
sending the next command.

Eight ASCII codes e CR

Command 4-digits:Command. The text of four characters.
Parameter 4-digits:Parameter 0 – 9, x, blank, ?

Parameter

Input the parameter values, aligning left, and fill with blank(s) for the remainder. (Be sure that four values are input for the
parameter.)
When the input parameter is not within an adjustable range, “ERR” returns. (Refer to “Response code format”.)
No problem to input any numerical value for “x” on the table.

When “?” is input for some commands, the present setting value responds.

C1 C2 C3 C4 P1 P2 P3 P4

0

0

5

5

1

0

0

Ϫ

3

0

0

0

0

9

0

?

?

?

?

?

Advertising