Sanyo PLC-WXE46 User Manual

Page 43

Advertising
background image

PLC-WXE46/WXL46

Expand Serial Command Functional Specifications

43/65

9.4.6

CR_GAMMA Command

Command "CR_GAMMA”[CR]

Details

Get Gamma value

of user control

Response

Acceptable

“000_%a”[CR]

%a

“000”~“015”

Unacceptable “Error code”[CR]

9.4.7

CR_WBAL – R Command

Command "CR_WBAL-R”[CR]

Details

Get White Balance Red value

of user control

Response

Acceptable

“000_%a”[CR]

%a

“000”~“063”

Unacceptable “Error code”[CR]

9.4.8

CR_WBAL – G Command

Command "CR_WBAL-G”[CR]

Details

Get White Balance Green value

of user control

Response

Acceptable

“000_%a”[CR]

%a

“000”~“063”

Unacceptable “Error code”[CR]

9.4.9

CR_WBAL – B Command

Command "CR_WBAL-B”[CR]

Details

Get White Balance Blue value

of user control

Response

Acceptable

“000_%a”[CR]

%a

“000”~“063”

Unacceptable “Error code”[CR]

9.4.10 CR_COLTEMP Command

Command "CR_COLTEMP”[CR]

Details

Get Color Temp. setting value

Response

Acceptable

“000_%a”[CR]

%a

“000” ------------------------------ Xlow
“001” ------------------------------ Low
“002” ------------------------------ Mid
“003” ------------------------------ High
“BLANK” -------------------- Adjusting White Balance

Unacceptable “Error code”[CR]