Soleus Air KC-18U User Manual
Page 15

13
115 volt(103.5min.-126.5max.)
0- 12 amperes
15-amp time-delay fuse or circuit breaker
14 gauge copper wiring
conformance with National Electrical Code, ANSI/NFPA 70-latest edition*, and
all local codes and ordinances.
Copies of the standards listed may be obtained from:
*National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Specific electrical requirements are listed in the chart. Follow the requirements for the
type of plug on the power supply cord.
Power supply cord plug outlet
Wiring requirements
230 volt(207 min.-253 max.)
230/208 volt(197.6 min.-253 max.)
0-16 amperes
20-amp time-delay fuse or double-pole circuit breaker
12 gauge copper wiring
230 volt(207 min.-253 max.)
230/208 volt(197.6 min.-253max)
0-24 amperes
30-amp time-delay fuse or circuit breaker
10 gauge copper wiring
230 volt (207min.-253 max.)
230/208 volt(197.6min.-253max.)
0-12 amperes
15-amp time-delay fuse or circuit breaker
14 gauge copper wiring