OUTPUT TERMINALS

TAPE END OUT Terminal

•

During recording, when the end of the tape is reached
or when the tape counter reading indicates 7 hours 57
minutes or more, the output becomes 0V (Low).

•

To reset the output, press the STOP or EJECT button.

•

During autorepeat recording, when the end of the tape
is reached, the output becomes 0V (Low) for about 2
seconds only.

TAPE END OUT Terminal Output Setting

1

Press the MENU button until the (SET UP 3) menu is
displayed.

@@@@@@@<SET@UP@3>

*ALARM@MODE@@@@@@@Y1

*ALARM@SPEED@@@@@@8H

*ALARM@DURATION@@@20S

*VERTICAL@SYNC@@@@Y

*EXT@TIME@ADJ.@@@@01:00

*TAPE@IN@MODE@@@@@STOP

*TAPE@END@MODE@@@@REW

*TAPE@END@OUT@@@@@-3M

*CLOG@DETECT.@@@@@Y

*SERIES@REC@IN@@@@N

2

Press the

]

button until the “TAPE END OUT” setting

is flashing.

3

Press the

l

(or

j

) button, to select the desired

output mode.

– 3M . . . . . . . . The output becomes 0 V (Low)

when the tape counter reaches
“7:57:00” and/or when the tape
reaches the end.

END . . . . . . . . The output becomes 0 V (Low)

when the tape reaches the end.

4

Press the PAUSE/SEARCH button to save the setting.

SW OUT Terminal

When recording, a pulse signal is output at the SW OUT
terminal.

This terminal is usually connected to the switch input (SW
IN) of devices like a camera switcher unit, or a quad
compressor.

SW OUT Terminal Output Setting

1

Press the MENU button until the (SET UP 4) menu is
displayed.

@@@@@@@<SET@UP@4>

*SW@OUT

@@TIMING@@@@@@@@@@FIELD

@@FIELD@@@@@@@@@@@01

@@8H@@@@@@@@@@@@@@Y

*THREAD@CHECK@@@@@Y

*VIDEO@LOSS@@@@@@@N

*REC@SPEED@@@@@@@@N

*EJECT@SET

@@EJECT@MODE@@@@@@EJECT1

@@OPERATION@@@@@@@SLAVE

2

Press the

l

(or

j

) button to set “FIELD” or “FRAME”,

then press the

]

button.

FIELD . . . . . . . 1 pulse is output after each set

number of fields.

FRAME. . . . . . 1 pulse is output after each set

number of frames.

3

Press the

l

(or

j

) button to set the desired pulse

signal interval, then press the

]

button.

•

If “TIMING” is set to FRAME (see step

2

),

“FRAME” will be indicated instead of “FIELD”.

Available settings are:

FIELD . . . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 field

FRAME. . . . . . 01, 02, 03, 04, 05, 10, 30 or 60

frame

4

Press the

l

(or

j

) button to set the desired “8H (or

6H)” mode.

•

If the “TAPE” in the (SET UP 5) menu is set to
“T-120”, “6H” will be indicated instead of “8H”.

Y . . . . . . . . . . . When recording in 8-hour (or

6-hour) mode, a pulse signal is
output.

N. . . . . . . . . . . When recording in 8-hour (or

6-hour) mode, a pulse signal is
not output.

5

Press the PAUSE/SEARCH button to save the
settings.

Tape end or 7:57:00

5V (H)

0V (L)

(Output impedance: 5.7 k

Ω

)

Output reset

5V (H)

0V (L)

(Output impedance: 5.7 k

Ω

)

FIELD: 16.7 msec.
FRAME: 5 msec.

NU4QG/NA3 (SRT-2400DC GB) Mon. Sept., 17/2001