Check probable causes action – Sarlo BC-8 User Manual

Page 12

Advertising
background image

10

TROUBLESHOOTING GUIDE

NOTES

Case 1. Starting failure

CHECK

PROBABLE CAUSES

ACTION

Fuel tank

➔

Incorrect fuel

➔

Drain it and fill with correct fuel

Fuel filter

➔

Fuel filter is clogged

➔

Clean

Carburetor idle speed screw

➔

Out of normal range

➔

Adjust to normal range

No spark

➔

Spark plug is fouled/wet

➔

Clean/dry

➔

Plug gap is incorrect

➔

[Correct GAP .025" (0.6~0.7 mm)]

Spark plug

➔

Disconnected

➔

Retighten

Case 2. Engine starts but does not keep running/Hard re-starting

CHECK

PROBABLE CAUSES

ACTION

Fuel tank

➔

Incorrect fuel or stale fuel

➔

Drain it and fill with correct fuel

Carburetor idle speed screw

➔

Out of normal range

➔

Adjust to normal range

Muffler, cylinder(exhaust port)

➔

Carbon is built-up

➔

Wipe away

Air cleaner

➔

Clogged with dust

➔

Wash

Cylinder fin, fan cover

➔

Clogged with dust

➔

Clean

If your unit needs further service, please consult with an authorized service dealer in your area.