Page E-1

X-Rack Line Return Module

E. The Line Return Module

E.1 Introduction

The X-Rack Line Return module is designed to operate in conjunction with the X-Rack XR622 Master

module to create an expandable, rack mounted, stereo line level mixer. The X-Rack Master module

provides the monitoring facilities that would be expected; mix amps, monitor outputs and a headphone

feed – please refer to the X-Rack Master module documentation for a full description.

E.2 Connection

The rear panel of the module carries a pair of 25-way ‘D’ connectors. The left-hand

connector provides four balanced Line Inputs whilst the right-hand connector

provides access to the Insert Send and Insert Returns for each of the four Line Inputs.
This module operates at a nominal level of +4dBu although the gain of each Line Input

or Insert Return can be varied by a front panel control.

E.3 Operation

The X-Rack Line Return module contains four separate input amplifiers, each

equipped with individual Gain and Pan controls as well as Insert, Solo and

Record/Mix bus switches.
The ‘LEVEL’ control

allows the gain of each input to be varied from –∞ to +10dB

with an indent at unity gain. A signal present indicator measures the signal level

immediately prior to the ‘LEVEL’ control. It will light GREEN for signals above the

lower threshold of –60dBu, AMBER for signals between +4dBu and +24dBu and

lights RED for signals above +24dBu.
Signals applied to the input of the module will be permanently available on the

Insert Send; the Insert Return can be selected in place of the Line Input by pressing

the ‘INS’ switch

. Note that the Insert Return can also be used to provide an

alternative input to each input amplifier.
Each input can be individually routed to either the Mix Bus (‘REC’ switch released)

or the Record Bus (‘REC’ switch pressed)

. The ‘SOLO’ switch feeds signal, post

Level and Pan, to the X-Rack Solo Bus. Each of the three busses feed the X-Rack

Master Module, located either in the same X-Rack or remotely if multiple X-Rack

units have been linked by the ‘MIX BUS LINK’ connector (please note that X-Rack

units prior to serial number XRK0110 are not equipped with an ‘MIX BUS LINK’

connector).
The ‘PAN’ control

will pan between Left and Right of the selected bus.

4

3

2

1

SEL

XR623

LEVEL

PAN

INS

REC

SOLO

LINE 1

LEVEL

PAN

INS

REC

SOLO

LINE 2

LEVEL

PAN

INS

REC

SOLO

LINE 3

LEVEL

PAN

INS

REC

SOLO

LINE 4

LINE IN

INSERT

SEND/

RTN

1 - 4

1

2

3

4

Advertising