Troubleshooting

Symptom

Possible Cause

Solution

No sound from

Incorrect input setting

Check setting of the Global/Local switch.

one zone

Bad speaker connection

LDS LED in bright green, swap speakers
from other zone to identify the problem.

Bad input connection

Swap inputs from other zone to identify
the problem.

Speaker output shorted, or too

LDS LED shall flash red, turn off unit

low speaker impedance

power, swap speakers from other zone,
then turn on the power again to identify
the problem.

Trigger switch set to 12V

Feed a 12V trigger signal to turn unit on,
or set the switch to “Music” or “on”
position.

Level adjust pot set too low

Turn both “L” and “R” level control up.

One channel out

Can possibility be any of the above

Check through above solutions.

Mode switch set at BRGD

Only R-channel will output if speakers
are connected at left and right for
stereo mode listening. Set the mode
mode switch to stereo for correction.