DUCTING REQUIREMENTS

•

Use a 4-inch (10.2 cm) diameter rigid aluminum or rigid galvanized steel duct.

•

Do not use a smaller duct.

•

Ducts larger than 4 inches (10.2 cm) in diameter can result in increased lint accumulation.

Lint accumulation should be cleaned regularly.

•

If a flexible metal duct must be used, use the type with a stiff sheet metal wall. Do not use a flexible

duct with a thin foil wall. Serious blockage can result if the flexible metal duct is bent too sharply.

•

Never install any type of flexible duct in walls, ceilings, or other concealed spaces.

•

Keep exhaust duct as straight and short as possible.

•

Secure joints with duct tape. Do not use screws.

•

DO NOT EXHAUST DRYER INTO ANY WALL, CEILING, CRAWL SPACE, OR CONCEALED SPACE OF A

BUILDING, GAS VENT, OR ANY OTHER COMMON DUCT OR CHIMNEY.

THIS COULD CREATE A FIRE HAZARD FROM LINT EXPELLED BY THE DRYER.

•

Plastic flexible duct can kink, sag, be punctured, reduce airflow, extend drying times, and affect dryer

operation.

•

Exhaust systems longer than recommended can extend drying times, affect machine operation, and

may collect lint.

•

The exhaust duct should end with an exhaust hood with a swing-out damper to prevent back drafts

and entry of wildlife. Never use an exhaust hood with a magnetic damper.

•

The hood should have at least 12 inches (30.5 cm) of clearance between the bottom of the hood and

the ground or other obstruction. The hood opening should point down.

•

Never install a screen over the exhaust outlet.

•

To avoid lint buildup, do not exhaust the dryer directly into a window well. Do not exhaust under a

house or porch.

•

If exhaust ductwork must run through an unheated area, the duct should be insulated and slope

slightly down towards the exhaust hood to reduce condensation and lint buildup.

•

Inspect and clean the interior of the exhaust system at least once a year. Unplug the power cord

before cleaning.

•

Check frequently to be sure the exhaust hood damper opens and closes freely.

•

Check once per month, and clean at least one time per year. Note: If clothes are not getting dry,

then check ducting for obstructions.

* Do not use non-metallic flexible duct.

ELECTRIC AND GAS DRYER

Weather Hood Type

Recommended

Use only for short-run installation

No. of 90°

elbows

Rigid

Metallic Flexible*

Rigid

Metallic Flexible*

0

24.4 m (80 ft.)

12.4 m (41 ft.)

22.6 m (74 ft.)

10.1 m (33 ft.)

1

20.7 m (68 ft.)

11.2 m (37 ft.)

18.9 m(62 ft.)

8.8 m (29 ft.)

2

17.4 m (57 ft.)

10.1 m (33 ft.)

15.5 m(51 ft.)

7.6 m (25 ft.)

3

14.3m (47 ft.)

9.0 m (29 ft.)

12.5 m(41 ft.)

6.5 m (21 ft.)

4” (10 .16 cm)

2.5” (6.35 cm)

DV316LGW-060103.indd 2

2006-01-06 ソタタ・8:54:21

Advertising