Siemens Industrial PC Simatic Panel PC 677B User Manual

Page 12

Advertising
background image

Installation / panel-mounting

3.3 Preparing the mounting cut-out

SIMATIC Panel PC 677B

12

Operating Instructions (Compact), 06/2008, A5E02217246-01

Table 3-2

Dimensions for the mounting cut-out in mm

Control

unit

L1

L2

L3

1)

L4

1)

L5

L6

2)

L7

2)

L8

2)

L9

2)

A1 A2 S1

S2

S3

S4

S5

3)

S6

3)

S7

3)

Tolerance

±1

+1

±0,2 ±0,2 ±0,5 ±0,5 ±0,5 ±0,5 +1

±1 ±1 ±1

±1

±1

±1

Key

panel

12" TFT

15" TFT

450

450

290

321

465

465

235

279

112

112

—

186

—

135

—

25

—

165

16

16

10

17

78

51

78

51

56

56

—

—

Touch

panel

12" TFT

15" TFT

17" TFT

19" TFT

368

450

450

450

290

290

380

380

—

465

465

465

—

235

235

235

112

112

112

112

—

—

—

—

—

—

—

—

—

—

—

—

—

—

—

—

16

16

16

16

10

10

10

10

19

81

46

46

35

81

46

46

56

56

—

—

—

—

33

33

1)

M6 thread or drill holes with a diameter of 7 mm

2)

Cut-outs for the shafts of the insert strips are only necessary for 15" key panels.

3)

Two clamps necessary for vertically securing clamps for 17" and 19" touch panels only.

Preparing the mounting cut-out

Steps for preparing the mounting cut-out
1 Select a location suitable for mounting, taking into account the mounting position.
2 On the basis of the dimensions, check whether the required screw and pressure points on the

rear and the seal area are easily accessible after the completion of the mounting cut-out.

Otherwise the mounting cut-out is useless.

3 Complete the mounting cut-out in accordance with the dimensions.

Advertising