Schumacher IP-180KE User Manual
Page 5

•
3
•
If the ring terminals were installed incorrectly, an audio alarm will sound.
•
DO NOT turn your IP-180KE on. This could cause serious damage. Re-
verse ring terminal connections and the audio alarm will stop.
If no audio alarm is sounded, turn ON the Jump Start switch and then
•
crank the engine. If the engine does not start within 5-8 seconds, stop
cranking and wait at least 1 minute before attempting to start vehicle
again. (This permits the battery to cool down.)
After the engine starts, make sure to turn OFF the Jump Start switch.
•
Disconnect Quick Connector.
•
CONTROL PANEL
5.
LED INDICATORS
6.
(R
ed
,
yellow
and
gReen
lights
)
To check the internal battery’s charge status, press the Battery Status But-
6.1
ton on the front of the Instant Power™.
The
6.2
LED lights will indicate the charge level as follows:
A red LED indicates a 50% or less charge and you should immediately
•
recharge the Instant Power™.
A yellow LED indicates a 50 to 75% charge. The Instant Power™ may be
•
used but should be recharged as soon as possible.
A green LED indicates the internal battery is fully charged.
•
CHARGING OF INTERNAL BATTERY WITH BUILT-IN CHARGER
7.
After removing the Instant Power™ from the carton, charge it for a mini-
7.1
mum of 8 hours before using, even if the green charged LED glows.
NOTE: The ON/OFF switch should be in the OFF position to recharge the
internal battery.